双有源桥DC/DC变换器的三移相优化控制Triple Phase Shift Optimization Control of Dual Active Bridge DC/DC Converter
张瑶,程志江,陈星志
摘要(Abstract):
针对隔离式双有源桥DC/DC变换器采用单移相控制时会产生较大的电感电流有效值,导致电路损耗增加,功率转换效率降低.文章提出了三移相优化控制策略,该控制策略是基于广义三移相控制三种有效工作模式的功率和电感电流有效值,根据优化方程分别计算得到高中低功率范围内的最优控制结果,分析出在高功率范围内单移相控制是电感电流有效值最小的最优控制,而中低功率范围内三移相优化控制是电感电流有效值最小最优控制.最后通过在MATLAB上建立仿真模型,通过仿真结果验证了在中低功率范围内此三移相优化控制相比较于单移相控制减小了电感电流有效值,从而提高双有源桥DC/DC变换器的转换效率.
关键词(KeyWords): DC/DC变换器;单移相控制;功率范围;三移相优化控制
基金项目(Foundation): 国家自然科学基金项目(51567022,51667020)
作者(Author): 张瑶,程志江,陈星志
DOI: 10.13568/j.cnki.651094.2019.03.013
参考文献(References):
- [1]高亮,张新燕,岳家辉,等.基于不同风况的双馈型风力发电机组并网谐波分析[J].新疆大学学报(自然科学版),2019,36(2):221-226.GAO L,ZHANG X Y,YUE J H,et al.Harmonic analysis of grid-connected wind turbine generators based on different wind conditions[J].Journal of Xinjiang University(Natural Science Edition),2019,36(2):221-226.
- [2]尹纯亚,李凤婷,张增强,等.直流闭锁引发多馈出直流系统换相失败分析[J].新疆大学学报(自然科学版),2019,36(2):138-145.YIN C Y,LI F T,ZHANG Z Q,et al.Analysis of commutation failure of multi-feed-out DC system induced by DC blocking[J].Journal of Xinjiang University(Natural Science Edition),2019,36(2):138-145.
- [3]DONCKER R W A A D,DIVAN D M,KHERALUWALA M H.A three-phase soft-switched high-power-density DC/DC converter for high-power applications[J].Industry Applications IEEE Transactions on,1991,27(1):63-73.
- [4]ZHAO B,QIANG S,LIU W,et al.Next-eneration multi-functional modular intelligent ups system for smart grid[J].IEEETransactions on Industrial Electronics,2013,60(9):3602-3618.
- [5]黄珺,王跃,高远.应用于储能系统的隔离型双向全桥直流变换器的软开关特性研究[J].电气传动,2013,43(S1):74-78.HUANG W,WANG Y,GAO Y.Research on soft-switching characteristics of isolated bidirectional full-bridge DC converter applied to energy storage system[J].Electric Drive,2013,43(S1):74-78.
- [6]ZHAO B,QIANG S,LIU W,et al.Overview of dual-active-bridge isolated bidirectional DC-DC converter for high-frequency-link power-conversion system[J].IEEE Transactions on Power Electronics,2014,29(8):4091-4106.
- [7]DE-DONCKER R W,DIVAN D M,KHERALUWALA M H.A three-phase soft-switched high power density DC-to-DD converter for high power applications[J].IEEE Transactions on Industry Applications,1991,27(1):63-73.
- [8]KHERALUWALA M H,GASCOIGNE R W,DIVAND M,et al.performance characterization of a high-power dual active bridge DC-to-DC converter[J].IEEE Transactions on Industry Applications,1992,28(6):1294-1301.
- [9]LI X,LI Y.An optimized phase-shift modulation for fast transient response in a dual-active-bridge converter[J].IEEE Transactions on Power Electronics,2014,29(6):2661-2665.
- [10]RODRIGUEZ A,VAZQUEZ A,LAMAR D G,et al.Different purpose design strategies and techniques to improve the performance of a dual active bridge with phase-shift control[J].IEEE Transactions on Power Electronics,2015,30(2):790-804.
- [11]ZHAO B,SONG Q,LIU W H,et al.current-stress-optimized switching strategy of isolated bidirectional DC/DC converter with dual-phase-shift control[J].IEEE Transactions on Industrial Electronics,2013,60(10):4458-4467.
- [12]JAIN A K,AYYANAR R.PWM control of dual active bridge:comprehensive analysis and experimental verification[J].IEEETransactions on Power Electronics,2011,26(4):1215-1227.
- [13]KRISMER F,KOLAR J W.Closed form solution for minimum conduction loss modulation of DAB converters[J].IEEE Transactions on Power Electronics,2012,7(1):174-188.
- [14]王亚檬.磁耦合谐振式无线电能传输系统的开发[D].太原:太原理工大学,2017.WANG Y M.Development of magnetically coupled resonant radio energy transmission system[D].Taiyuan:Taiyuan University of Technology,2017.